Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 33
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Craniofac Surg ; 2024 Apr 23.
Artículo en Inglés | MEDLINE | ID: mdl-38651891

RESUMEN

Fishbone foreign body (FFB) can lodge in the upper respiratory or gastrointestinal tracts and frequently cause discomfort. While FFBs are common, variations in the hyoid may present radiographically similarly. The authors present a case in which a 32-year-old woman presented with pain in the right neck with a globus sensation after eating fish. Examination, including flexible fiberoptic laryngoscopy, did not reveal a foreign body. Given the patients' persistent symptoms, a noncontrast computed tomography was performed, demonstrating a radiopaque body superior to the right lateral hyoid bone, consistent with FFB. Direct examination under anesthesia was performed, and no FFB was noted. A reassessment of the imaging suggested a likely aberrant hyoid bone. The authors report this case to remind clinicians that while rare, aberrant hyoid variants may mimic FFB. The authors also review the imaging findings of aberrant hyoid variants in this report, as recognition of hyoid variability can mitigate unnecessary intervention.

2.
J Appl Crystallogr ; 57(Pt 1): 60-70, 2024 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-38322717

RESUMEN

Developing semiconductor devices requires a fast and reliable source of strain information with high spatial resolution and strain sensitivity. This work investigates the strain in an axially heterostructured 180 nm-diameter GaInP nanowire with InP segments of varying lengths down to 9 nm, simultaneously probing both materials. Scanning X-ray diffraction (XRD) is compared with Bragg projection ptychography (BPP), a fast single-projection method. BPP offers a sufficient spatial resolution to reveal fine details within the largest segments, unlike scanning XRD. The spatial resolution affects the quantitative accuracy of the strain maps, where BPP shows much-improved agreement with an elastic 3D finite element model compared with scanning XRD. The sensitivity of BPP to small deviations from the Bragg condition is systematically investigated. The experimental confirmation of the model suggests that the large lattice mismatch of 1.52% is accommodated without defects.

3.
Sci Rep ; 13(1): 16516, 2023 10 02.
Artículo en Inglés | MEDLINE | ID: mdl-37783694

RESUMEN

Bacterial colonization is mediated by fimbriae, which are thin hair-like appendages dispersed from the bacterial surface. The aggregative adherence fimbriae from enteroaggregative E. coli are secreted through the outer membrane and consist of polymerized minor and major pilin subunits. Currently, the understanding of the structural morphology and the role of the minor pilin subunit in the polymerized fimbriae are limited. In this study we use small-angle X-ray scattering to reveal the structural morphology of purified fimbriae in solution. We show that the aggregative fimbriae are compact arrangements of subunit proteins Agg5A + Agg3B which are assembled pairwise on a flexible string rather than extended in relatively straight filaments. Absence of the minor subunit leads to less compact fimbriae, but did not affect the length. The study provides novel insights into the structural morphology and assembly of the aggregative adherence fimbriae. Our study suggests that the minor subunit is not located at the tip of the fimbriae as previously speculated but has a higher importance for the assembled fimbriae by affecting the global structure.


Asunto(s)
Escherichia coli , Proteínas Fimbrias , Proteínas Fimbrias/metabolismo , Escherichia coli/metabolismo , Dispersión del Ángulo Pequeño , Difracción de Rayos X , Adhesión Bacteriana , Fimbrias Bacterianas/metabolismo
4.
ACS Appl Nano Mater ; 6(19): 17698-17705, 2023 Oct 13.
Artículo en Inglés | MEDLINE | ID: mdl-37854855

RESUMEN

Metal halide perovskites (MHPs) have garnered significant interest as promising candidates for nanoscale optoelectronic applications due to their excellent optical properties. Axially heterostructured CsPbBr3-CsPb(Br(1-x)Clx)3 nanowires can be produced by localized anion exchange of pregrown CsPbBr3 nanowires. However, characterizing such heterostructures with sufficient strain and real space resolution is challenging. Here, we use nanofocused scanning X-ray diffraction (XRD) and X-ray fluorescence (XRF) with a 60 nm beam to investigate a heterostructured MHP nanowire as well as a reference CsPbBr3 nanowire. The nano-XRD approach gives spatially resolved maps of composition, lattice spacing, and lattice tilt. Both the reference and exchanged nanowire show signs of diverse types of ferroelastic domains, as revealed by the tilt maps. The chlorinated segment shows an average Cl composition of x = 66 and x = 70% as measured by XRD and XRF, respectively. The XRD measurements give a much more consistent result than the XRF ones. These findings are consistent with photoluminescence measurements, showing x = 73%. The nominally unexchanged segment also has a small concentration of Cl, as observed with all three methods, which we attribute to diffusion after processing. These results highlight the need to prevent such unwanted processes in order to fabricate optoelectronic devices based on MHP heterostructures.

5.
J Am Chem Soc ; 145(29): 15754-15765, 2023 Jul 26.
Artículo en Inglés | MEDLINE | ID: mdl-37163700

RESUMEN

Resolving the structural dynamics of bond breaking, bond formation, and solvation is required for a deeper understanding of solution-phase chemical reactions. In this work, we investigate the photodissociation of triiodide in four solvents using femtosecond time-resolved X-ray solution scattering following 400 nm photoexcitation. Structural analysis of the scattering data resolves the solvent-dependent structural evolution during the bond cleavage, internal rearrangements, solvent-cage escape, and bond reformation in real time. The nature and structure of the reaction intermediates during the recombination are determined, elucidating the full mechanism of photodissociation and recombination on ultrafast time scales. We resolve the structure of the precursor state for recombination as a geminate pair. Further, we determine the size of the solvent cages from the refined structures of the radical pair. The observed structural dynamics present a comprehensive picture of the solvent influence on structure and dynamics of dissociation reactions.

6.
J Appl Crystallogr ; 56(Pt 2): 449-460, 2023 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-37032973

RESUMEN

Serial femtosecond crystallography was initially developed for room-temperature X-ray diffraction studies of macromolecules at X-ray free electron lasers. When combined with tools that initiate biological reactions within microcrystals, time-resolved serial crystallography allows the study of structural changes that occur during an enzyme catalytic reaction. Serial synchrotron X-ray crystallography (SSX), which extends serial crystallography methods to synchrotron radiation sources, is expanding the scientific community using serial diffraction methods. This report presents a simple flow cell that can be used to deliver microcrystals across an X-ray beam during SSX studies. This device consists of an X-ray transparent glass capillary mounted on a goniometer-compatible 3D-printed support and is connected to a syringe pump via light-weight tubing. This flow cell is easily mounted and aligned, and it is disposable so can be rapidly replaced when blocked. This system was demonstrated by collecting SSX data at MAX IV Laboratory from microcrystals of the integral membrane protein cytochrome c oxidase from Thermus thermophilus, from which an X-ray structure was determined to 2.12 Šresolution. This simple SSX platform may help to lower entry barriers for non-expert users of SSX.

7.
Opt Express ; 30(23): 42308-42322, 2022 Nov 07.
Artículo en Inglés | MEDLINE | ID: mdl-36366687

RESUMEN

We demonstrate how the individual mirrors of a high-quality Kirkpatrick-Baez (KB) mirror system can be aligned to each other to create an optimally focused beam, through minimizing aberrations in the phase of the ptychographically reconstructed pupil function. Different sources of misalignment and the distinctive phase artifacts they create are presented via experimental results from the alignment of the KB mirrors at the NanoMAX diffraction endstation. The catalog of aberration artifacts can be used to easily identify which parameter requires further tuning in the alignment of any KB mirror system.

8.
J Synchrotron Radiat ; 29(Pt 3): 876-887, 2022 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-35511021

RESUMEN

The diffraction endstation of the NanoMAX beamline is designed to provide high-flux coherent X-ray nano-beams for experiments requiring many degrees of freedom for sample and detector. The endstation is equipped with high-efficiency Kirkpatrick-Baez mirror focusing optics and a two-circle goniometer supporting a positioning and scanning device, designed to carry a compact sample environment. A robot is used as a detector arm. The endstation, in continued development, has been in user operation since summer 2017.

9.
Nanoscale ; 14(13): 5247, 2022 Mar 31.
Artículo en Inglés | MEDLINE | ID: mdl-35319063

RESUMEN

Correction for 'Strain mapping inside an individual processed vertical nanowire transistor using scanning X-ray nanodiffraction' by Dmitry Dzhigaev et al., Nanoscale, 2020, 12, 14487-14493, DOI: 10.1039/D0NR02260H.

10.
Nat Commun ; 13(1): 724, 2022 Feb 07.
Artículo en Inglés | MEDLINE | ID: mdl-35132068

RESUMEN

Efficient manipulation of antiferromagnetic (AF) domains and domain walls has opened up new avenues of research towards ultrafast, high-density spintronic devices. AF domain structures are known to be sensitive to magnetoelastic effects, but the microscopic interplay of crystalline defects, strain and magnetic ordering remains largely unknown. Here, we reveal, using photoemission electron microscopy combined with scanning X-ray diffraction imaging and micromagnetic simulations, that the AF domain structure in CuMnAs thin films is dominated by nanoscale structural twin defects. We demonstrate that microtwin defects, which develop across the entire thickness of the film and terminate on the surface as characteristic lines, determine the location and orientation of 180∘ and 90∘ domain walls. The results emphasize the crucial role of nanoscale crystalline defects in determining the AF domains and domain walls, and provide a route to optimizing device performance.

11.
Adv Mater ; 34(15): e2106826, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-35064954

RESUMEN

The combination of strain and electrostatic engineering in epitaxial heterostructures of ferroelectric oxides offers many possibilities for inducing new phases, complex polar topologies, and enhanced electrical properties. However, the dominant effect of substrate clamping can also limit the electromechanical response and often leaves electrostatics to play a secondary role. Releasing the mechanical constraint imposed by the substrate can not only dramatically alter the balance between elastic and electrostatic forces, enabling them to compete on par with each other, but also activates new mechanical degrees of freedom, such as the macroscopic curvature of the heterostructure. In this work, an electrostatically driven transition from a predominantly out-of-plane polarized to an in-plane polarized state is observed when a PbTiO3 /SrTiO3 superlattice with a SrRuO3 bottom electrode is released from its substrate. In turn, this polarization rotation modifies the lattice parameter mismatch between the superlattice and the thin SrRuO3 layer, causing the heterostructure to curl up into microtubes. Through a combination of synchrotron-based scanning X-ray diffraction imaging, Raman scattering, piezoresponse force microscopy, and scanning transmission electron microscopy, the crystalline structure and domain patterns of the curved superlattices are investigated, revealing a strong anisotropy in the domain structure and a complex mechanism for strain accommodation.

12.
J Synchrotron Radiat ; 28(Pt 6): 1948-1953, 2021 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-34738950

RESUMEN

The CoSAXS beamline at the MAX IV Laboratory is a modern multi-purpose (coherent) small-angle X-ray scattering (CoSAXS) instrument, designed to provide intense and optionally coherent illumination at the sample position, enabling coherent imaging and speckle contrast techniques. X-ray tracing simulations used to design the beamline optics have predicted a total photon flux of 1012-1013 photons s-1 and a degree of coherence of up to 10% at 7.1 keV. The normalized degree of coherence and the coherent flux of this instrument were experimentally determined using the separability of a ptychographic reconstruction into multiple mutually incoherent modes and thus the Coherence in the name CoSAXS was verified. How the beamline can be used both for coherent imaging and XPCS measurements, which both heavily rely on the degree of coherence of the beam, was demonstrated. These results are the first experimental quantification of coherence properties in a SAXS instrument at a fourth-generation synchrotron light source.

13.
J Synchrotron Radiat ; 28(Pt 6): 1935-1947, 2021 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-34738949

RESUMEN

NanoMAX is the first hard X-ray nanoprobe beamline at the MAX IV laboratory. It utilizes the unique properties of the world's first operational multi-bend achromat storage ring to provide an intense and coherent focused beam for experiments with several methods. In this paper we present the beamline optics design in detail, show the performance figures, and give an overview of the surrounding infrastructure and the operational diffraction endstation.

14.
J Synchrotron Radiat ; 28(Pt 4): 1253-1260, 2021 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-34212891

RESUMEN

The emergence of fourth-generation synchrotrons is prompting the development of new systems for experimental control and data acquisition. However, as general control systems are designed to cover a wide set of instruments and techniques, they tend to become large and complicated, at the cost of experimental flexibility. Here we present Contrast, a simple Python framework for interacting with beamline components, orchestrating experiments and managing data acquisition. The system is presented and demonstrated via its application at the NanoMAX beamline of the MAX IV Laboratory.

15.
Science ; 372(6542): 630-635, 2021 05 07.
Artículo en Inglés | MEDLINE | ID: mdl-33858991

RESUMEN

Unconventional ferroelectricity exhibited by hafnia-based thin films-robust at nanoscale sizes-presents tremendous opportunities in nanoelectronics. However, the exact nature of polarization switching remains controversial. We investigated a La0.67Sr0.33MnO3/Hf0.5Zr0.5O2 capacitor interfaced with various top electrodes while performing in situ electrical biasing using atomic-resolution microscopy with direct oxygen imaging as well as with synchrotron nanobeam diffraction. When the top electrode is oxygen reactive, we observe reversible oxygen vacancy migration with electrodes as the source and sink of oxygen and the dielectric layer acting as a fast conduit at millisecond time scales. With nonreactive top electrodes and at longer time scales (seconds), the dielectric layer also acts as an oxygen source and sink. Our results show that ferroelectricity in hafnia-based thin films is unmistakably intertwined with oxygen voltammetry.

16.
J Appl Crystallogr ; 53(Pt 6): 1444-1451, 2020 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-33304222

RESUMEN

Ptychographic X-ray computed tomography is a quantitative three-dimensional imaging technique offered to users of multiple synchrotron radiation sources. Its dependence on the coherent fraction of the available X-ray beam makes it perfectly suited to diffraction-limited storage rings. Although MAX IV is the first, and so far only, operating fourth-generation synchrotron light source, none of its experimental stations is currently set up to offer this technique to its users. The first ptychographic X-ray computed tomography experiment has therefore been performed on the NanoMAX beamline. From the results, information was gained about the current limitations of the experimental setup and where attention should be focused for improvement. The extracted parameters in terms of scanning speed, size of the imaged volume and achieved resolutions should provide a baseline for future users designing nano-tomography experiments on the NanoMAX beamline.

17.
ACS Nano ; 14(11): 15973-15982, 2020 Nov 24.
Artículo en Inglés | MEDLINE | ID: mdl-33074668

RESUMEN

The interest in metal halide perovskites has grown as impressive results have been shown in solar cells, light emitting devices, and scintillators, but this class of materials have a complex crystal structure that is only partially understood. In particular, the dynamics of the nanoscale ferroelastic domains in metal halide perovskites remains difficult to study. An ideal in situ imaging method for ferroelastic domains requires a challenging combination of high spatial resolution and long penetration depth. Here, we demonstrate in situ temperature-dependent imaging of ferroelastic domains in a single nanowire of metal halide perovskite, CsPbBr3. Scanning X-ray diffraction with a 60 nm beam was used to retrieve local structural properties for temperatures up to 140 °C. We observed a single Bragg peak at room temperature, but at 80 °C, four new Bragg peaks appeared, originating in different real-space domains. The domains were arranged in periodic stripes in the center and with a hatched pattern close to the edges. Reciprocal space mapping at 80 °C was used to quantify the local strain and lattice tilts, revealing the ferroelastic nature of the domains. The domains display a partial stability to further temperature changes. Our results show the dynamics of nanoscale ferroelastic domain formation within a single-crystal perovskite nanostructure, which is important both for the fundamental understanding of these materials and for the development of perovskite-based devices.

18.
Nano Lett ; 20(11): 8326-8331, 2020 Nov 11.
Artículo en Inglés | MEDLINE | ID: mdl-33084341

RESUMEN

Nanoscale X-ray detectors could allow higher resolution in imaging and diffraction experiments than established systems but are difficult to design due to the long absorption length of X-rays. Here, we demonstrate X-ray detection in a single nanowire in which the nanowire axis is parallel to the optical axis. In this geometry, X-ray absorption can occur along the nanowire length, while the spatial resolution is limited by the diameter. We use the device to make a high-resolution 3D image of the 88 nm diameter X-ray nanofocus at the Nanomax beamline, MAX IV synchrotron, by scanning the single pixel device in different planes along the optical axis. The images reveal fine details of the beam that are unattainable with established detectors and show good agreement with ptychography.

19.
Nanoscale ; 12(27): 14487-14493, 2020 Jul 16.
Artículo en Inglés | MEDLINE | ID: mdl-32530025

RESUMEN

Semiconductor nanowires in wrapped, gate-all-around transistor geometry are highly favorable for future electronics. The advanced nanodevice processing results in strain due to the deposited dielectric and metal layers surrounding the nanowires, significantly affecting their performance. Therefore, non-destructive nanoscale characterization of complete devices is of utmost importance due to the small feature sizes and three-dimensional buried structure. Direct strain mapping inside heterostructured GaSb-InAs nanowire tunnel field-effect transistor embedded in dielectric HfO2, W metal gate layers, and an organic spacer is performed using fast scanning X-ray nanodiffraction. The effect of 10 nm W gate on a single embedded nanowire with segment diameters down to 40 nm is retrieved. The tensile strain values reach 0.26% in the p-type GaSb segment of the transistor. Supported by the finite element method simulation, we establish a connection between the Ar pressure used during the W layer deposition and the nanowire strain state. Thus, we can benchmark our models for further improvements in device engineering. Our study indicates, how the significant increase in X-ray brightness at 4th generation synchrotron, makes high-throughput measurements on realistic nanoelectronic devices viable.

20.
Opt Express ; 28(4): 5069-5076, 2020 Feb 17.
Artículo en Inglés | MEDLINE | ID: mdl-32121735

RESUMEN

The NanoMAX hard X-ray nanoprobe is the first beamline to take full advantage of the diffraction-limited storage ring at the MAX IV synchrotron and delivers a high coherent photon flux for applications in diffraction and imaging. Here, we characterize its coherent and focused beam using ptychographic analysis. We derive beam profiles in the energy range 6-22 keV and estimate the coherent flux based on a probe mode decomposition approach.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...